Immersed V2.2 control box
Ref. IM Coffret V2.2
Power supply
Backlit screen
Dry contact for electrolyser control and pump control contact
Surge protection
Backlit screen
Dry contact for electrolyser control and pump control contact
Surge protection
Technical
specifications
- 230 VAC – 50/60 Hz supply voltage
- Motor supply voltage : 30Vdc max (regulation via the board)
- Power input :
– in standby : 5W
– under max load : 600W
- Current load :
– in standby : 30mA
– under max load : 3A
- On/off button
- Potentiometer of speed control
- Surge protection
- Working temperature : 0° up to + 50°C
- Storage temperature : -20°C up to +60°C
Box
- IP54
- Easy wiring
- Fixing nuts included
Standards-compliant
• According to NF P90-308 the box complies with the provisions of the European guidelines:
- “Low voltage” provision 2014/35/UE
- “Electromagnetic compatibility” 2014/30/UE
In order to provide a maximum hold against lightning strike, these products are qualified according to the EN 61000-4-4 (level 4) and EN 61000-4-5 (level 4) standards.